Tobii Quickstart TobiiGlasses2QuickStart 24042017 ENGus Web

Transcript

1 What’s in the Carry Case? Tobii Pro Glasses 2 c b d Quick Start Guide e a f g j l k d i h g 1 x Head Unit 1 x Calibration card a 1 x Recording Unit 1 x Microfiber cleaning cloth h b + 1 1 clear x Protective lenses ( 2 1 x Head Strap c i ) ; 1 attached to the Head Unit tinted 1 x USB memory stick with 6 x Nose Pads in 3 different sizes j d documentation and software 3 x Rechargeable Li-Ion batteries 1 x Cable cord clip e k type 18650 1 x HDMI A to HDMI D cable 3 x SD memory cards + sleeves f l

2 What’s in the Carry Case? What’s in the Accessories Box? Preparing and Connecting Tobii Pro Glasses 2 1 - Charge the batteries Recording Unit preparation 2 - 3 - Attach the Nose Pad c b d 3 2 4 Gently squeeze the nose pads together and insert the Nose Pad Insert the batteries into the charger. The battery is fully charged 5 into the two holes on the head unit. when the icon below is displayed on the screen: Insert SD e memory card. a The different color stickers indicate the 3 different sizes. Please choose the appropriate V size for the participant. Install charged battery. f 4 - Software installation 6 - Head Unit preparation Powering the Recording Unit 5 - 1 g Step 1 Insert HDMI cable. Optional j l k d i h Head Strap. Step 2 Download, install and open “Tobii Pro Glasses g Insert the HDMI cable, then press and hold the power 1 x Head Unit 1 x Calibration card a Controller” on your Windows tablet/computer. button for a few seconds or until the LEDs stop flashing to turn on your Recording Unit. Secure cable www.tobiipro.com/downloads 6 8 7 in clip. 1 x Recording Unit 1 x Microfiber cleaning cloth h b The unit is connected to the Tobii Pro Glasses Controller and ready to start a Recording Unit LEDs recording. Connecting to your device 7 - (Connection LED solid green) The Recording Unit is (SD LED off) The SD Memory Card ready or the Recording Wireless 1 x Battery charger for Li-Ion connected to Tobii Pro Glasses Controller. 4 x Power plugs for USB Unit is powered off. Protective lenses 1 + x 1 clear ( 2 Find and connect to your Pro Glasses 2 via WLAN. 1 x Head Strap c 1 5 i Wired (SD LED blinking green) The Recording Unit is busy writing (EU, US, UK + AUS) charger batteries (Connection LED off) The Recording Unit is disconnected 1 attached to the Head Unit ; ) tinted (Look on the back of the Recording Unit for the to the SD Memory Card. Do NOT remove the SD Memory from Tobii Pro Glasses Controller. Card. serial number, this will be the name of the WLAN If using a wired Step 2 network.) connection, securely (Power LED off) The Recording Unit is turned off. All other (SD LED blinking green) Missing SD Memory Card. Insert an LED indicators are off. SD Memory Card. 1 x USB memory stick with connect the Ethernet 1 x Ethernet cable (3 Meters) 1 x USB Ethernet Adapter 6 x Nose Pads in 3 different sizes Step 1 j 6 2 cable to the Recording d documentation and software (SD LED solid yellow) The SD Memory Card has critically (Power LED solid green) The battery is good or charging. Unit and to your low storage. SD Memory Card change recommended. computer. (SD LED blinking yellow) The Recording Unit is busy writing (Power LED solid yellow) The battery running out of power. to an SD Memory Card which has critically low storage. 5 x Power cables for battery Battery change recommended 3 x Rechargeable Li-Ion batteries Stop recording and change the SD Memory Card. 2 x Calibration cards 1 x Cable cord clip e 7 3 k (LED blinking yellow) The battery is critical. Change the charger (EU, US, UK + AUS) type 18650 (SD LED solid red) The SD Memory Card is corrupted. battery. Change the SD memory card. (SD LED blinking red) The SD Memory Card is Read-Only. (LED Slow blinking) No power to the Head Unit. Ensure the The WLAN password for your Tobii 1 x USB charger for Recording Remove lock or replace the SD Memory Card. head unit is connected correctly. 10 x Calibration stickers Pro Glasses 2 is “ TobiiGlasses ” 1 x HDMI A to HDMI D cable 3 x SD memory cards + sleeves 8 4 f l Unit with a capital T and G.

3 d Recor Par ticipants Dashboar 1 h 46 min (35%) Liv dings e View er 19 - Doug 001 Study Recor ding Stamper Field 3 h 30 min 1 h 57 min #4 Gla sses Calibrating and Recording with Tobii Pro Glasses 2 Tobii Pro Lab Analyzer Edition What’s in the Accessories Box? Preparing and Connecting Tobii Pro Glasses 2 1 - Charge the batteries Recording Unit preparation 2 - Attach the Nose Pad 3 - Creating a new recording 1 - Software installation 1 - Calibrat e the p ar ticip ant 3 2 4 Start up the “Tobii Pro Glasses Controller”. If this is your first ever recording, create a new Gently squeeze the nose pads together and insert the Nose Pad Insert the batteries into the charger. The battery is fully charged 5 Step 1 Step 2 Project before proceeding. Then press “Start New Recording” on the relevant pair of Tobii into the two holes on the head unit. when the icon below is displayed on the screen: Pro Glasses 2. Insert SD Type the participant’s name and relevant info, then press “Create”. memory card. The different color stickers indicate the 3 different sizes. Please choose the appropriate V size for the participant. Install charged battery. Remove the SD memory card from your Recording Unit and Download, install and open “Tobii Pro Lab Analyzer Make sure the Calib ration Target insert it into your computer Edition” on your Windows tablet/computer. provided is focused by the participant and tap the www.tobiipro.com/downloads Recor dings Par ticipants 1 h 46 min (35%) d Liv e View er Dashboar “Calib rate” button bel ow. Head Unit preparation 4 - Software installation 6 - Powering the Recording Unit 5 - 1 dings 1 h 46 min (35%) Par ticipants Dashboar d Liv e View er Recor Calibrating a participant 2 - Field Study 001 Stamper 19 - Doug ding Recor Step 1 3 h 30 min 1 h 57 min sses Gla #4 2 - 3 - Import your data Create a project Step 1 0.50m - 1.50m Field ding Recor 19 - Doug 001 Stamper Study Recor Par ticipants 1 h 46 min (35%) er e View Liv d Dashboar dings Insert (1.65ft - 4.9ft) Gently fit the Head HDMI cable. 1 h 57 min 3 h 30 min Step 3 Gla sses #4 Unit onto the Hold the calibration card participant as shown and have the participant Study Stamper 19 - Doug ding Field 001 Recor below. Exchange the Optional Cancel Calibrate focus on the center Nose Pad if necessary. Head Strap. point... 3 h 30 min 1 h 57 min Gla #4 sses Step 2 Step 4 ...then press the Successful calibration! calibrate button and Download, install and open “Tobii Pro Glasses allow the Insert the HDMI cable, then press and hold the power Controller” on your Windows tablet/computer. calibration process button for a few seconds or until the LEDs stop to complete. You flashing to turn on your Recording Unit. are now ready to Secure cable www.tobiipro.com/downloads 6 8 7 start recording. Step 2 in clip. Gently attach the Recording The unit is connected to the Tobii Pro Glasses Controller and ready to start a Unit to the participant’s belt Recording Unit LEDs recording. or clothing. 7 - Connecting to your device (Connection LED solid green) The Recording Unit is (SD LED off) The SD Memory Card ready or the Recording Wireless 1 x Battery charger for Li-Ion connected to Tobii Pro Glasses Controller. 4 x Power plugs for USB Unit is powered off. Find and connect to your Pro Glasses 2 via WLAN. 1 5 Wired (SD LED blinking green) The Recording Unit is busy writing (EU, US, UK + AUS) charger batteries (Connection LED off) The Recording Unit is disconnected (Look on the back of the Recording Unit for the to the SD Memory Card. Do NOT remove the SD Memory Start a recording Stop a recording 3 - 4 - from Tobii Pro Glasses Controller. Card. serial number, this will be the name of the WLAN If using a wired To stop a recording, press the stop button. If the calibration is successful, press the record Step 2 Tap “Record” network.) connection, securely (Power LED off) The Recording Unit is turned off. All other (SD LED blinking green) Missing SD Memory Card. Insert an button. LED indicators are off. SD Memory Card. ew rec to start a n ording connect the Ethernet You have now completed a recording with 1 x Ethernet cable (3 Meters) 1 x USB Ethernet Adapter Step 1 6 2 cable to the Recording the Tobii Pro Glasses 2. (If not, ask the participant to look at the calibration (SD LED solid yellow) The SD Memory Card has critically (Power LED solid green) The battery is good or charging. Unit and to your low storage. SD Memory Card change recommended. target again then press the recalibrate button.) computer. (SD LED blinking yellow) The Recording Unit is busy writing (Power LED solid yellow) The battery running out of power. to an SD Memory Card which has critically low storage. 5 x Power cables for battery Battery change recommended Stop recording and change the SD Memory Card. 2 x Calibration cards 7 3 (LED blinking yellow) The battery is critical. Change the charger (EU, US, UK + AUS) (SD LED solid red) The SD Memory Card is corrupted. Using the “Tobii Pro Lab Analyzer Edition” choose a At the Project Dashboard press “Import > Glasses battery. Change the SD memory card. name for your new project and where to save it, then Recording”. Locate and select the data file (*.ttgp) on the SD press create. memory card to import it. (SD LED blinking red) The SD Memory Card is Read-Only. (LED Slow blinking) No power to the Head Unit. Ensure the The WLAN password for your Tobii 1 x USB charger for Recording Remove lock or replace the SD Memory Card. head unit is connected correctly. Cancel Record Realib rate Stop Pause Cancel 10 x Calibration stickers TobiiGlasses ” Pro Glasses 2 is “ 8 4 You are now ready to begin analyzing your data. Unit with a capital T and G. Stop Pause Cancel

4 Dashboar Liv Par ticipants dings Recor er e View d 1 h 46 min (35%) Stamper 19 - Doug ding Recor 001 Study Field 3 h 30 min 1 h 57 min sses Gla #4 Calibrating and Recording with Tobii Pro Glasses 2 Tobii Pro Lab Analyzer Edition Preparing and Connecting Tobii Pro Glasses 2 1 - Charge the batteries 2 - Recording Unit preparation 3 - Attach the Nose Pad 1 - Creating a new recording Software installation 1 - Calibrat e the p ar ticip ant Start up the “Tobii Pro Glasses Controller”. If this is your first ever recording, create a new Gently squeeze the nose pads together and insert the Nose Pad Insert the batteries into the charger. The battery is fully charged Step 1 Step 2 Project before proceeding. Then press “Start New Recording” on the relevant pair of Tobii into the two holes on the head unit. when the icon below is displayed on the screen: Pro Glasses 2. Insert SD Type the participant’s name and relevant info, then press “Create”. memory card. The different color stickers indicate the 3 different sizes. Please choose the appropriate V size for the participant. Install charged battery. Remove the SD memory card from your Recording Unit and Download, install and open “Tobii Pro Lab Analyzer Make sure the Calib ration Target insert it into your computer Edition” on your Windows tablet/computer. provided is focused by the participant and tap the www.tobiipro.com/downloads Par ticipants Liv Dashboar dings d 1 h 46 min (35%) er Recor e View “Calib rate” button bel ow. 4 - Software installation 6 - Head Unit preparation 5 - Powering the Recording Unit Liv Recor er e View Par ticipants d Dashboar 1 h 46 min (35%) dings 2 - Calibrating a participant 001 Study Field Recor ding 19 - Doug Stamper Step 1 3 h 30 min 1 h 57 min #4 sses Gla 3 - Create a project 2 - Import your data Step 1 0.50m - 1.50m Stamper 19 - Doug Field ding Recor Study 001 er Dashboar d Liv e View 1 h 46 min (35%) Recor dings Par ticipants Insert (1.65ft - 4.9ft) Gently fit the Head HDMI cable. 1 h 57 min 3 h 30 min Step 3 Gla #4 sses Unit onto the Hold the calibration card participant as shown and have the participant Stamper 19 - Doug ding Recor Field Study 001 below. Exchange the Optional Cancel Calibrate focus on the center Nose Pad if necessary. Head Strap. point... 3 h 30 min 1 h 57 min sses #4 Gla Step 2 Step 4 ...then press the Successful calibration! calibrate button and Download, install and open “Tobii Pro Glasses allow the Insert the HDMI cable, then press and hold the power Controller” on your Windows tablet/computer. calibration process button for a few seconds or until the LEDs stop to complete. You flashing to turn on your Recording Unit. are now ready to Secure cable www.tobiipro.com/downloads start recording. Step 2 in clip. Gently attach the Recording The unit is connected to the Tobii Pro Glasses Controller and ready to start a Unit to the participant’s belt Recording Unit LEDs recording. or clothing. 7 - Connecting to your device (Connection LED solid green) The Recording Unit is (SD LED off) The SD Memory Card ready or the Recording Wireless connected to Tobii Pro Glasses Controller. Unit is powered off. Find and connect to your Pro Glasses 2 via WLAN. Wired (SD LED blinking green) The Recording Unit is busy writing (Connection LED off) The Recording Unit is disconnected (Look on the back of the Recording Unit for the to the SD Memory Card. Do NOT remove the SD Memory Start a recording Stop a recording 3 - 4 - from Tobii Pro Glasses Controller. Card. serial number, this will be the name of the WLAN If using a wired To stop a recording, press the stop button. If the calibration is successful, press the record Step 2 Tap “Record” network.) connection, securely (Power LED off) The Recording Unit is turned off. All other (SD LED blinking green) Missing SD Memory Card. Insert an button. LED indicators are off. SD Memory Card. ew rec to start a n ording connect the Ethernet You have now completed a recording with Step 1 cable to the Recording the Tobii Pro Glasses 2. (If not, ask the participant to look at the calibration (SD LED solid yellow) The SD Memory Card has critically (Power LED solid green) The battery is good or charging. Unit and to your low storage. SD Memory Card change recommended. target again then press the recalibrate button.) computer. (SD LED blinking yellow) The Recording Unit is busy writing (Power LED solid yellow) The battery running out of power. to an SD Memory Card which has critically low storage. Battery change recommended Stop recording and change the SD Memory Card. (LED blinking yellow) The battery is critical. Change the (SD LED solid red) The SD Memory Card is corrupted. Using the “Tobii Pro Lab Analyzer Edition” choose a At the Project Dashboard press “Import > Glasses battery. Change the SD memory card. name for your new project and where to save it, then Recording”. Locate and select the data file (*.ttgp) on the SD press create. memory card to import it. (SD LED blinking red) The SD Memory Card is Read-Only. (LED Slow blinking) No power to the Head Unit. Ensure the The WLAN password for your Tobii Remove lock or replace the SD Memory Card. head unit is connected correctly. Cancel Realib rate Record Pause Stop Cancel TobiiGlasses ” Pro Glasses 2 is “ You are now ready to begin analyzing your data. with a capital T and G. Stop Pause Cancel

5 Tobii Pro Lab Analyzer Edition Please see the USB memory stick included in your package for software, a full User Manual, Software installation 1 - and an instructional video. These are also WEB Step 2 Step 1 available online at: NGus_ www.tobiipro.com/support 24042017_E Remove the SD memory card from your Recording Unit and Download, install and open “Tobii Pro Lab Analyzer insert it into your computer Edition” on your Windows tablet/computer. www.tobiipro.com/downloads _TobiiProGlasses2QuickStartGuide_ Import your data 2 - 3 - Create a project QuickStart Tobii_ ® ©Tobii lo cal market. Techni cal specifications are subject to change without prior notice. All other trademarks are the property of their respective owners. and services . offered in products to apply necessarily not do specifications and Illu strations each Pro Support Tobii AMERI CA JAPAN NORT H CHINA GLOBAL / OPE EUR Using the “Tobii Pro Lab Analyzer Edition” choose a At the Project Dashboard press “Import > Glasses 950 522 8 +1 +46 (SWE): Pho ne 703 738 1320 Pho ne: +81 3 5793 3316 Pho ne: +86 180 1558 5168 10 Pho ne: 24 75 03 4 - 27 Pho ne (GER) : +49 69 name for your new project and where to save it, then Recording”. Locate and select the data file (*.ttgp) on the SD m [email protected] support [email protected] tobi support i.com @tobi support i.com [email protected] support i.com press create. memory card to import it. - Su pport 6 pm Su pport hou rs : 8 am - 8 pm Su pport hou rs : 9 am - 5.30 pm hou rs : 8 am Between Augu st : +9) GMT Time, Standa rd (Japa n July 6) - GMT Time, St anda rd Ea stern (US 5pm - 9am - +1) GMT Time, ean Eu rop (Centra l You are now ready to begin analyzing your data.

Related documents

911 Call Logs   2017 Updated

911 Call Logs 2017 Updated

Fire and EMS 24 Hour Call Report 2019-04-10 through 2019-05-09 Address Problem City Call Date Call Time Incident Number 2019-05-09 < 100 block of HOSPITAL DR 5/9/2019 12:34:40 AM 37A02 Level I Transfe...

More info »
htkbook

htkbook

The HTK Book Steve Young Gunnar Evermann Dan Kershaw Gareth Moore Julian Odell Dave Ollason Dan Povey Valtcho Valtchev Phil Woodland The HTK Book (for HTK Version 3.2) c © COPYRIGHT 1995-1999 Microsof...

More info »
Vital Statistics Reference Guidance, Number 2, May, 2019

Vital Statistics Reference Guidance, Number 2, May, 2019

Vital Statistics Reporting Guidance ■ Report No. 2 May 2019 A Reference Guide for Completing the Death Certificate for Drug Toxicity Deaths By following the instructions provided in this Reference Gui...

More info »
2017 1011 EEB Revisions to RP 6.7 Records of the University RP 5.10 FERPA  (00019133.DOC;1)

2017 1011 EEB Revisions to RP 6.7 Records of the University RP 5.10 FERPA (00019133.DOC;1)

University of Nebraska Board of Regents Policies Contains Amendments through March 29, 2019

More info »
Lesbian, Gay, Bisexual, Transgender, Queer, and HIV Affected Intimate Partner Violence in 2015

Lesbian, Gay, Bisexual, Transgender, Queer, and HIV Affected Intimate Partner Violence in 2015

Lesbian, Gay, Bisexual, Transgender, Queer, and HIV-Affected Intimate Partner Violence in 2015 A report from the National Coalition of Anti-Violence Programs 2016 Release Edition

More info »
May 01 2019

May 01 2019

For Date: 05/01/2019 - Wednesday Call Time Call Reason Action Number - 0054 EXTRA PATROL No Problems Noted/Nothing New 16129 19 Location/Address: MILTON RD Post: DWARD5 - Arvd - 01:05:58 00:55:01 Clrd...

More info »
avianflu

avianflu

FOR STATE USE ONLY # Novel Influenza A such as H5N1 confirmed  COUNTY ___/___/___ case report presumptive  suspect  ___/___/___ interstate CASE IDENTIFICATION (check all that apply) SOURCES OF REPO...

More info »
Duodenoscope Investigation FINAL Report

Duodenoscope Investigation FINAL Report

United States Senate ENSIONS EALTH E DUCATION , L ABOR , H P , C OMMITTEE AND Patty Murray, Ranking Member Preventable Tragedies : Superbugs and How Ineffective Monitoring of Medical Device Safety Fai...

More info »
credit profile report

credit profile report

Product sheet Credit Profile Report Precise data. Unsurpassed file coverage. You can’t make the best decisions if you don’t have the best information. That’s where we come in. With Experian’s Credit P...

More info »
Geology of St. John, U.S. Virgin Islands

Geology of St. John, U.S. Virgin Islands

3:33 PM P1631cover.qxd Page 1 5/16/03 D U.S. Department of the Interior U.S. Geological Survey irgin Islands Geology of St. John, U.S. V Rankin—GEOLOGY U.S. GEOLOGICAL SURVEY PROFESSIONAL P APER 1631 ...

More info »
Uranium 2014: Resources, Production and Demand

Uranium 2014: Resources, Production and Demand

A Joint Report by the OECD Nuclear Energy Agency and the International Atomic Energy Agency Uranium 2014: Resources, Production and Demand U ranium 2014: Resources, Production and Demand N E A

More info »
Alcoholics Anonymous Second Edition

Alcoholics Anonymous Second Edition

ALCOHOLICS ANONYMOUS The Story of How Many Thousa Men and Women nds of Have Recovered fr om Alcohol ism NEW AND REV ISE D EDIT ION ALCOHOL ICS ANONYMOUS WORL D SERVICE S, I NC. NEW YOR K CITY 1955

More info »
DataWindow

DataWindow

D/T Arrested D/T Arrested D/T Arrested D/T Arrested Page 1 of 19 CN# CN# CN# CN# 19005408 04/30/2019 16:15 17023727 04/30/2019 11:00 19089030 05/01/2019 00:20 19089030 05/01/2019 00:20 19008292 04/30/...

More info »
07 5123 06 zigbee cluster library specification

07 5123 06 zigbee cluster library specification

ZigBee Cluster Library – 075123 Document ZigBee Cluster Library Specification Revision 6 Draft Version 1.0 - 0125 Chapter Document: 14 5123 - 07 ZigBee Document: 06 - ZigBee Document 07 - 5123 201 4 J...

More info »
ayout 1

ayout 1

0465039146-FM:FM 12/5/06 12:25 AM Page i C O D E

More info »
AI Now Report 2018   Published Version   Locked   Google Docs

AI Now Report 2018 Published Version Locked Google Docs

t 2018 AI Now Repor er , AI Now Institute, New Y ork Univ ersity , Google Open Resear ch Mer edith Whittak awfor , AI Now Institute, New Y ork Univ ersity , Micr osoft Resear ch d Kate Cr , AI Now Ins...

More info »
JO 7400.11C   Airspace Designations and Reporting Points

JO 7400.11C Airspace Designations and Reporting Points

U.S. DEPARTMENT OF TRANSPORTATION ORDER FEDERAL AVIATION ADMINISTRATION 7400.11C JO Air Traffic Organization Policy August 13, 2018 SUBJ: Airspace Designations and Reporting Points . This O rder, publ...

More info »
DataWindow

DataWindow

D/T Arrested 05/02/2019 11:35 D/T Arrested D/T Arrested D/T Arrested Page 1 of 19 CN# CN# CN# CN# 19004620 05/03/2019 02:42 19090593 05/02/2019 22:45 19DOC1563 16002019 05/02/2019 08:25 :00 05/03/2019...

More info »
fast18 failSlowHw

fast18 failSlowHw

Fail-Slow at Scale: Evidence of Hardware Performance Faults in Large Production Systems 1 2 2 1 , Casey Golliher Haryadi S. Gunawi , , Russell Sears , Riza O. Suminto 4 4 5 3 , Xing Lin , , Weiguang S...

More info »
Chapter 3 - More About Alcoholism - (pp. 30-43)

Chapter 3 - More About Alcoholism - (pp. 30-43)

Chapter 3 MORE ABOUT ALCOHOLISM have been unwilling to admit we ost of us M were real alcoholics. No person likes to think he is bodily and mentally different from his fellows. Ther efore, it is not s...

More info »